View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0001788 | K18X001.00 SKB SWAN | General | public | 2023-08-08 20:30 | 2025-04-07 10:09 |
| Reporter | (ALTech) SH Son | Assigned To | (MFG) An Tran | Due Date | |
| Priority | normal | Severity | s4-minor | Reproducibility | have not tried |
| Status | closed | Resolution | fixed | ||
| Summary | 0001788: [SWAN][MP] Grill assy quality issue | ||||
| Description | [SWAN][MP] Grill assy quality issue | ||||
| Tags | No tags attached. | ||||
| Attach Tags | |||||
| User List |
(ALTech) BY Lee , (ALTech) Hyunsik Kim , (ALTech) JW Kim , (ALTech) Lonnie Kim , (ALTech) SH Son , (ALTech) Sophie Lee , |
|---|
|
|
Here is communication history |
|
|
Hi Son I would like to send test results with photos for each FT1 color balance test NG case. : Color balance = (value color min/ value color max)*100% 1. Reference (OK) 2. NG A. 92% B. 90% C. 85% D. 80% Thanks |
|
|
Hi An, Please return to vender (ZYX VN) these NG samples. total 10pcs. and remind that, each grill(front) should be marking the number and all signed (Factory). to avoid the mix other grill(front) samples from vender. These samples have to review in Korea site. Thanks SON |
|
|
Hi Son Pls help review the test result. 1. Test result : In the case of color balance test NG last tested total 195 /559pcs , The test report the color balance test result for each LED 1 to 11. ( Att file ) 2. One more question, What about the right side LED test results? Only left test results were reported. => The right side LED also had test results similar to the left side LED. Therefore, we are only reporting on the left sile LED, Thanks Rachel Ruan |
|
|
Hi SH Son I would like to send you the data of failure after reducing the spec to 90 as the file NG rate is too high, cut off time at 09:00 08/14 Input 650pcs, passed 439pcs NG 211pcs. NG rate 32% Please kindly help to review and tell us instruction Thanks |
|
|
Hi SH Son I would like to update the NG quantity and cpk as the attached file. Please kindly help to review it and let me know instruction. Thanks |
|
|
Hi SH Son I would like to send you report about SWAN Led Light abnormal as the attached file. Total we already finshed 4K units SMT and found out this issue. Please kindly help to review and arrange your time to discuss with Fii team. Thanks |
|
|
Hi all Update paper #10 |
|
|
HI An, Today as we discussion, Please provide vender(EVERLIGHT) FA report that why white color is different. after review the vender FA report, we will continue to discussion about SWAN LED Light abnormal. Thanks SON |
|
|
Hi SH Please see attached the report. Base on SWAN's spec, LED is acceptable. Please help to review this report and let us know your decision. Our production line is still holding for this issue. Thanks for you support Miya |
|
|
Hi Miya and An. I have some question about this Q1. Please report LED used HUE code of Swan so far production. Q2. How to manage HUE code management during production? Q3. about DC_230624 bin code range, it looks spec out. Please explain more details that why reported normal? Thanks SON |
|
|
about DC_230624 bin code range spec out |
|
|
Hi SH Son I would like to upload BFX-UA300 Verify Led Light analysis as the file. Please kindly help to review it. Thanks |
|
|
Hi Son I have some question about this Q1. Please report LED used HUE code of Swan so far production. [An] We sent email to vendor update it and provide next week before 08/31 Q2. How to manage HUE code management during production? [An] We have the left 5K not SMT yet. We will control them by DC and MO(Manufacturing Order) Q3. about DC_230624 bin code range, it looks spec out. Please explain more details that why reported normal? [An] DC 230624, there are some out bin code 257 but still in bin code 239. This bin code is in of 16 bin code so still in standard. |
|
|
HI An and Miya, basically understand using different HUE code. but this is only one LED is used in the product. My point of view to solve the issue, I need to check the following - Different HUE codes for one product should not be applied - Different HUE codes cannot be applied to the same production lot (MO) - Different production specifications for each HUE code that's why I request HUE code management. We understand to finish the remaining production this year. first check if all remaining quantities can be produced with the same HUE code. THanks SON |
|
|
Hi SH Son I Would like to update the CPK for LED as the attached file. And bin code of 8K production from Jun to now. Please kindly review it and let me know if have issue. Thanks An Tran |
|
|
Hi An Tran about 0001788:0013995 We are reviewed and discuss this report, Please do control run color balance test spec adjust 90% to 85% As a result of this control run, will determine the limited test spec of this year. And can you send the LED PCBA below list? I want to review at Korea using these PCBA. 2023-08-16 16:17:40 2639009704 LDFL10 A8934AFF1F1A 2023-08-25 20:26:48 2639010616 LDFL10 A8934AFF2A07 2023-08-25 20:11:56 2639010616 LDFL10 A8934AFF29EA 2023-08-16 20:30:46 2639010616 LDFL10 A8934AFF2A7C 2023-08-25 20:21:06 2639010616 LDFL10 A8934AFF2AAE 2023-08-25 19:36:46 LDFL10 ?? Thanks SON |
|
|
Hi SH Son I would like to update the CPK of control run that you informed revised spec to 85 as the file. 6.5% failures related to front housing. Need vendor improve quality. Please kindly review it and let me know your instructions Thanks An |
|
|
Hi Son I update the DC and Bin code as the file. Green is DC for this this control run Thanks |
|
|
Hi An, Thank you for your reports, I confirm the waiver for color balance test spec 90% to 85% but, this waiver is only for this year production. for the next year production, continue to discuss 0001788:0013992 and update the color balance test spec. Please note that, ALT and Inkel was agreed replace NG housing immediately. if factory find the NG housing, please mark the "NG" on the housing. because to do not reuse at vender side. Thanks SON |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2023-08-08 20:30 | (ALTech) SH Son | New Issue | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) BY Lee | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) Hyunsik Kim | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) JW Kim | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) Lonnie Kim | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) SH Son | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) Sophie Lee | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) Sun Choul Joung | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (ALTech) SY Yoon | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (MFG) An Tran | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (MFG) Ben Trinh | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (MFG) Rachel Ruan | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (MFG) Toney Tu | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (PM) Dennis Lu | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (PM) Roisy Liang | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (PM) Sheila Tu | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (PM) Tiffanie Lai | |
| 2023-08-09 09:59 | (ALTech) SH Son | Issue Monitored: (Sales) Miya Wang | |
| 2023-08-09 09:59 | (ALTech) SH Son | Assigned To | => (MFG) An Tran |
| 2023-08-09 09:59 | (ALTech) SH Son | Status | new => assigned |
| 2023-08-09 10:00 | (ALTech) SH Son | Note Added: 0013849 | |
| 2023-08-09 10:00 | (ALTech) SH Son | File Added: RE_ BFX-AU300 - K18X001_00 Led faint cause Housing incoming abnormal issue_.msg | |
| 2023-08-09 12:24 | (MFG) An Tran | Note Added: 0013855 | |
| 2023-08-09 12:24 | (MFG) An Tran | File Added: Housing issue.7z | |
| 2023-08-09 16:33 | (ALTech) SH Son | Note Added: 0013860 | |
| 2023-08-09 16:43 | (MFG) Rachel Ruan | Note Added: 0013861 | |
| 2023-08-09 16:43 | (MFG) Rachel Ruan | File Added: K18X001.00 Led issue CPK.xlsx | |
| 2023-08-14 10:03 | (SW) Jacky Chiang | Severity | s2-severe => s4-minor |
| 2023-08-14 15:38 | (MFG) An Tran | Note Added: 0013879 | |
| 2023-08-14 15:38 | (MFG) An Tran | File Added: L18X001.00 LED issue.xlsx | |
| 2023-08-15 16:19 | (MFG) An Tran | Note Added: 0013880 | |
| 2023-08-15 16:19 | (MFG) An Tran | File Added: L18X001.00 LED issue_Update.xlsx | |
| 2023-08-16 10:26 | (MFG) An Tran | Note Added: 0013887 | |
| 2023-08-16 10:26 | (MFG) An Tran | File Added: SWAN Led Light abnormal.pptx | |
| 2023-08-16 12:07 | (MFG) An Tran | Note Added: 0013889 | |
| 2023-08-16 12:07 | (MFG) An Tran | File Added: SWAN Led Light abnormal-2.pptx | |
| 2023-08-16 17:00 | (ALTech) SH Son | Note Added: 0013893 | |
| 2023-08-23 22:58 |
|
Note Added: 0013962 | |
| 2023-08-23 22:58 |
|
File Added: 8E230800023_0822 越南Foxconn 19-137-R6GHBHC-S1906-2T(HFX) K18X001色差藍綠_0823.pdf | |
| 2023-08-24 09:14 | (ALTech) SH Son | Note Added: 0013969 | |
| 2023-08-24 09:34 | (ALTech) SH Son | Note Added: 0013972 | |
| 2023-08-24 09:34 | (ALTech) SH Son | File Added: image.png | |
| 2023-08-24 17:31 | (HW) Sean Chiang | Issue Monitored: (HW) Sean Chiang | |
| 2023-08-24 17:31 | (HW) Sean Chiang | Issue Monitored: (HW) Cooper Kung | |
| 2023-08-24 17:31 | (HW) Sean Chiang | Issue Monitored: (RD) Jay Lin | |
| 2023-08-25 14:18 | (MFG) An Tran | Note Added: 0013989 | |
| 2023-08-25 14:18 | (MFG) An Tran | File Added: BFX-UA300 Verify Led Light abnormal.pptx | |
| 2023-08-25 14:50 | (MFG) An Tran | Note Added: 0013991 | |
| 2023-08-25 15:19 | (ALTech) SH Son | Note Added: 0013992 | |
| 2023-08-26 16:54 | (MFG) An Tran | Note Added: 0013995 | |
| 2023-08-26 16:54 | (MFG) An Tran | File Added: image-2.png | |
| 2023-08-26 16:54 | (MFG) An Tran | File Added: SWAN CPK verify LED.xlsx | |
| 2023-08-28 16:10 | (ALTech) SH Son | Note Added: 0014007 | |
| 2023-08-28 16:10 | (ALTech) SH Son | File Added: image-3.png | |
| 2023-08-29 14:43 | (MFG) An Tran | Note Added: 0014014 | |
| 2023-08-29 14:43 | (MFG) An Tran | File Added: SWAN CPK CTR verify spec.xlsx | |
| 2023-08-29 14:43 | (MFG) An Tran | File Added: image-4.png | |
| 2023-08-29 15:31 | (MFG) An Tran | Note Added: 0014015 | |
| 2023-08-29 15:31 | (MFG) An Tran | File Added: image-5.png | |
| 2023-08-29 15:31 | (MFG) An Tran | File Added: LED DC Bin code.xls | |
| 2023-08-29 16:51 | (ALTech) SH Son | Note Added: 0014017 | |
| 2025-04-07 10:09 | (PM) Sheila Tu | Status | assigned => closed |
| 2025-04-07 10:09 | (PM) Sheila Tu | Resolution | open => fixed |